多氣體培養(yǎng)箱:
MG-70M
IR CO2 sensor and zirconia O2 sensors realize high precised hypoxic culture.
MG-70M
Two gas cylinders connectable. Automatic cylinder changer are standardized in all models.
|
Each model can attach a shelf up to six.
(Images of 3 shelves attached)
|
|
Main Application
●Mammalian cell culture
●For research of iPS and cancer
Features
Possible highly precise hypoxic culture
This O2 sensor is not using conventional galvanic battery but zirconia battery which is stable for a long time and high sensitivity. It has a quick response and shortens the lead time of validation when installed and transition time to hypoxic condition.
●Quick transition to hypoxic condition
In MG-70M, the graph shows transition of DO inside PBS put on the same chamber until the DO inside the chamber goes up to set value.
It was verified that faster attainment than equivalent models of competitors(refer to values on each catalog) and its data agreed with theoretical values (O2 partial pressure between gas and liquid phase).
●Apoptosis data in hypoxic culture
PC12 cells to which apoptosis is induced by hypoxia condition. The hypoxic environment was confirmed by cultivation at 9 points in MG-70M.
Left panel: green arrowheads indicate apoptotic cells and white arrows indicate necrotic cells
Right panel: percentage of apoptotic and necrotic cells
Representative data were shown.
Dissolved oxygen (DO) database inside
It is installed of referencial data about DO concentration of several patterns inside the culturing containers when set at 37℃ .
By combination with non-invasive O2 sensor makes it possible to monitor DO, pH and CO2 in hypoxic culture.
Outstanding cost effectiveness and automatic cylinder changer
A cultivation performance is equivalent with other established companies with lower cost. For example, when two cylinders were connected and one side was consumed,it is automatically canged to new cylinder.
In 70M, CO2 and N2 (or O2) are connectable each two cylinders.
Specifications
Model
|
MG-70M
|
Temperature Range
|
Ambient+5oC to +50oC
|
Temp. Control Accuracy
|
±0.1 oC
|
Heating System
|
Heating method: airjacket
Humidification method: natural evaporation by trays
|
CO2 Sensor
|
IR CO2 sensor
|
CO2 Range
|
0 to 20% (above atmosphere), Digital display, Increment: 0.1%
|
O2 Sensor
|
Zirconia O2 sensor
|
O2 Range
|
1-25%(*1), Digital display
|
Dimensions
|
457×543×632Hmm
|
Inner Dimension
|
Chamber:320×410×400Hmm
|
Capacity
|
Capacity: 70L
Vessel availability: for example, 49 x φ35mm petri dish or 6 well plates or 14 x 25 cm2 TC per shelf.
|
Other Functions
|
Hole for power supply cable etc. x1, Automatic change of cylinder, Date base of DO
|
Standard Accessory
|
Shelf x 3
|
(*1)Depending on the conditions of CO2, it may not be stabilized in 18 - 22% of range. O2 gas cylinder is required for set above atmospheric concentration and N2 gas cylinder for set below atmosphere.
●Two levels stackable.
●MG-70M can attach a shelf up to six.
●MG-70M can be modified to cGMP standard.